Deflection/Span Ratio Tests - positive and negative wind pressures are applied to the face of the window to test the maximum deflection limits. Operating Force Tests - to verify that an opening sash is capable of
opening and closing without undue effort. Air Infiltration Tests - the air leakage of a window is tested to ensure energy and acoustic efficiency. Water Penetration Tests - this test is designed to ensure no water leaks through the window into the building. Ultimate Strength Tests - negative and positive wind pressures are applied to the window at 1.5 times the designed wind pressure to ensure it does not fail in unusual wind conditions. Vipac has the facilities and experience in both Melbourne and Singapore to submit full-scale models to extensive testing to verify the strength and durability of windows, including structural performance as well as air and water infiltration. During these tests, sample windows are subjected to high wind and driving rain simulations, air infiltration pressure, operating force and ultimate proof testing. Acoustic certification tests to rate sound insulation or sound transmission loss can be conducted in Vipac's reverberation chamber to ensure the tested window will keep out low frequency noise from traffic, aircrafts and trains. Vipac is also conducting energy rating tests and security ranking of windows and doors. |
Melbourne Test Facilities - 3 Separate Test Rigs
|
|
Flat |
Corner |
|
Test Rigs |
2 |
1 |
|
Window / Door Size |
600x600mm up to 6,000x8,000mm |
up to 3,000x2,700x2,000mm |
|
Air Pressure |
0 to +/- 4kpa in steps of 100pa |
|
|
Rain |
0 to 3.4 litres/hour/m2 |
|
|
Instrumentation |
Digital data acquisition system 4 - 64 channels |
|
Singapore Test Facilities - 7 Separate Test Rigs
|
|
Flat |
Corner |
Modular |
|
Test Rigs |
2 |
1 |
4 |
|
Window / Door Size |
600x600mm up to 12,000x15,000mm |
up to 3000x2700x2000mm |
|
|
Air Pressure |
0 to +/- 8kpa in steps of 100pa |
||
|
Rain |
0 to 3.4 litres/hour/m2 |
||
|
Instrumentation |
Digital data acquisition system 4 - 128 channels |
||
To find out more about these services, please email: