NATA Accreditation

Site No. 1499 – ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service

Product

Determinant

Technique

Procedure

Limitations

Evaluation of air control equipment

Air conditioning and ventilation systems

Air flow

Not applicable

  • ASHRAE 55
  • ASHRAE 70
  • ASHRAE 113
  • ASHRAE 130
  • ISO 5219
  • ISO 7730
  • AS 4740
  • ADC FD72
  • ARI 650
  • BS 4797 Part 1

Dampers

Cyclic test; Dynamic closure; Leakage; Operation; Temperature degradation

Not applicable

  • UL 555
  • BS EN 1751
  • ISO 10294
  • AS 1682.1
  • SS 333

Fans

Air delivery; Air flow; Fan speed and power

Not applicable

  • Air delivery, fan speed and power of electric circulating fans for household and similar use, excluding ceiling-type fans, to AS 2071-1984
  • Air flow measurement of fans and blowers using ASHRAE 51-75 nozzles, pitot tubes
  • Air flow measurement of gas fired ducted air heaters using ASHRAE 51-75 nozzles to AS 4556 and AG 106 (M.O.T.5.13.1-96)
  • BS 848 Part 1
  • ISO 5801

Air flow measurements with least uncertainties of measurement of:

  • 6% from 0.01 to 1.0 m³/s using orifice plates;
  • 4% from 0.05 to 1.0 m³/s using ASHRAE 51-75 nozzles;
  • 10% from 2 to 5 m³/s using pitot tubes;
  • 4% from 5 to 50 m³/s using pitot tubes;
  • 10% from 0.2 to 2 m³/s using hot-wire anemometers;
  • 5% from 2 to 10 m³/s using hot-wire anemometers;
  • 20% from 0.2 to 20 m³/s using vane anemometers

Site No. 1499 – ISO/IEC 17025 (2017)

Manufactured Goods

Service

Product

Determinant

Technique

Procedure

Limitations

Acoustic performance evaluation of products

Air conditioners and heat pumps; Air distribution products; Building materials and elements of construction

Sound pressure level

Not applicable

  • BS 4718:1971 (Clauses 2.3 and 3 only)
  • BS EN ISO 7235 (Clauses 6.2.1, 6.3 and 6.4 only)
  • BS 4856 Part 4
  • ADC 1062 R4
  • ARI 880 (Sound power components only)
  • ARI 885 (Sound power components only)
  • ARI 890 (Sound power components only)
  • ISO 3741:1999 (Broadband Noise measurements only)
  • ISO 3741 (Broadband Noise measurements only)
  • AS 1217.2:1985
  • AS 1277:1983

Static and dynamic insertion loss and generated noise level of air distribution system silencers, fan coil units, unit heaters and unit coolers; ISO 3741 over the frequency ranges:

  • 63 Hz to 8 kHz in one third octave bands
  • 63 Hz to 8 kHz in octave bands

Mechanical performance evaluation of components for building envelopes, framing and interior lining

Door, window and skylight assemblies

Air infiltration; Deflection; Operating force; Proof load; Strength at ultimate limit state loading; Structural performance evaluation; Water penetration resistance

Cyclic pressure; Static pressure

  • AS/NZS 4420.1
  • AS 2047 Section 2

Facade assemblies including interior and exterior cladding systems

Air infiltration; Deflection; Proof load; Strength at ultimate limit state loading; Structural performance evaluation; Water penetration resistance

Cyclic pressure; Static pressure

Including on-site tests to:

  • AS/NZS 4284 Sections 8.2, 8.3, 8.4, 8.5, 8.6, 8.8 and Appendices C, D, E (CSIRO SIROWET procedure)
  • NCC Building Code of Australia (Volume 1, Section FV1 and Volume 2, Section V2.2.1)

Facade assemblies including interior and exterior cladding systems; Wall, floor and ceiling panels

Water penetration resistance

Field check – Spray

Including on-site tests to:

  • AAMA 501.2

Site No. 21177 – ISO/IEC 17025 (2017)

Manufactured Goods

Service

Product

Determinant

Technique

Procedure

Limitations

Electrical equipment approval and safety evaluation

Audio, video and similar electronic equipment; Information technology equipment

Electrical safety

Dimensional assessment including creepage and clearance; Electrical characteristics; Energy measurement; Fire hazard assessment; Firmware assessment; Function assessment including abnormal operation; Insulation and electrical protection measurement; Mechanical assessment; Temperature; Visual examination

  • AS/NZS 62368.1 (excluding radiation measurements)
  • IEC 62368-1

Electrical appliances, coupling devices and accessories; Enclosures for electrical equipment

Electrical safety

Dimensional assessment including creepage and clearance; Electrical characteristics; Endurance and resistance to external conditions; Energy measurement; Fire hazard assessment; Firmware assessment; Function assessment including abnormal operation; Insulation and electrical protection measurement; Mechanical assessment; Temperature; Visual examination

  • AS/NZS 3100
  • AS/NZS 60335.1 (excluding Clauses 19.11.4; 22.201 and Annexes F; H)
  • AS/NZS 60335.2.2
  • AS/NZS 60335.2.3
  • AS/NZS 60335.2.5
  • AS/NZS 60335.2.6
  • AS/NZS 60335.2.7
  • AS/NZS 60335.2.9
  • AS/NZS 60335.2.10
  • AS/NZS 60335.2.11
  • AS/NZS 60335.2.13
  • AS/NZS 60335.2.14
  • AS/NZS 60335.2.15
  • AS/NZS 60335.2.21
  • AS/NZS 60335.2.23
  • AS/NZS 60335.2.24
  • AS/NZS 60335.2.29
  • AS/NZS 60335.2.30
  • AS/NZS 60335.2.31
  • AS/NZS 60335.2.35
  • AS/NZS 60335.2.40
  • AS/NZS 60335.2.41
  • AS/NZS 60335.2.45
  • AS/NZS 60335.2.60
  • AS/NZS 60335.2.61
  • AS/NZS 60335.2.65 (excluding Clauses 16.101, 22.103, 23.101, 32, Annex AA)
  • AS/NZS 60335.2.75
  • AS/NZS 60335.2.78
  • AS/NZS 60335.2.80
  • AS/NZS 60335.2.84
  • AS/NZS 60335.2.95
  • AS/NZS 60335.2.97
  • AS/NZS 60335.2.98
  • AS/NZS 60335.2.102
  • AS/NZS 60335.2.103
  • AS/NZS IEC 60670.1
  • IEC 60335-1 (excluding Clause 19.11.4 and Annexes F; H)
  • IEC 60335-2-2
  • IEC 60335-2-3
  • IEC 60335-2-5
  • IEC 60335-2-6
  • IEC 60335-2-7
  • IEC 60335-2-9,
  • IEC 60335-2-10
  • IEC 60335-2-11
  • IEC 60335-2-13
  • IEC 60335-2-14
  • IEC 60335-2-15
  • IEC 60335-2-21
  • IEC 60335-2-23
  • IEC 60335-2-24
  • IEC 60335-2-29
  • IEC 60335-2-30
  • IEC 60335-2-31
  • IEC 60335-2-35
  • IEC 60335-2-40
  • IEC 60335-2-41
  • IEC 60335-2-45
  • IEC 60335-2-60
  • IEC 60335-2-61
  • IEC 60335-2-65 (excluding Clause 16.101, 22.103, 23.101, 32, Annex AA)
  • IEC 60335-2-75
  • IEC 60335-2-78
  • IEC 60335-2-80
  • IEC 60335-2-84
  • IEC 60335-2-95
  • IEC 60335-2-97
  • IEC 60335-2-98
  • IEC 60335-2-102
  • IEC 60335-2-103
  • IEC 60670-1

Electrical appliances, coupling devices and accessories; Enclosures for electrical equipment; Laboratory and electromedical equipment

Effect of environmental exposure on electrical equipment and enclosures

Cold; Damp heat; Dry heat; Humidity; Shock (impact); Temperature; Vibration

  • AS IEC 60068:2003
  • AS IEC 60068.2.1
  • AS IEC 60068.2.2
  • AS IEC 60068.2.6
  • AS IEC 60068.2.27
  • AS IEC 60068.2.30
  • AS IEC 60068.2.64
  • AS IEC 60068.2.78
  • Temperature in the range -70ºC to +180ºC;
  • Relative humidity in the range 5 to 97% RH between 5ºC and 70ºC
  • Vibration – broad band random, sinusoidal and transient (shock)

Electrical appliances, coupling devices and accessories; Power tools – Electric

Degree of protection – IP rating

Not applicable

  • AS 60529
  • IEC 60529

Electrical cables, cords and conductors; Electrical plugs, sockets, lead assemblies and related components

Electrical performance of electrical cables, cords and conductors; Electrical safety of electrical cables, cords and conductors

Ageing; Bending; Combustion propagation; Compatibility; Conductor resistance; Contaminants; Current; Cutting; Density; Dielectric; Dimensions; Durability of markings; Electrical continuity; Flexing; Heat shock; Heating cycling; High voltage; Hot set; Ignitability; Immersion; Impact; Impulse voltage withstand; Insulation resistance; Load cycle; Mass; Partial discharge; Pressure testing; Sequence impedance; Shrinkage; Spark; Surface leakage; Temperature; Tensile strength; Vertical flame propagation; Voids; Voltage; Volume resistivity; Water absorption; Wrapping

  • AS/NZS 3191
  • AS/NZS 3808 – excluding the following tests:
    • Exudation of plasticizer
    • Acid and corrosive gas emission
    • Melt flow index
    • Carbon black content
    • Environmental stress crack resistance
  • AS/NZS 5000.1 (Working voltages up to and including 0.6/1 (1.2) kV)
  • AS/NZS 5000.2 (Working voltages up to and including 450/750 V)
  • AS/NZS 5000.3
  • AS/NZS 1125 (excluding clause 2.2)
  • AS/NZS 1660.1
  • AS/NZS 1660.2.1
  • AS/NZS 1660.2.2
  • AS/NZS 1660.2.3
  • AS/NZS 1660.3
  • AS/NZS 1660.4
  • AS/NZS 1660.5.6 (2005)
  • AS/NZS IEC 60332.1.1
  • AS/NZS IEC 60332.1.2
  • AS/NZS IEC 60332.1.3
  • AS/NZS 3808 – excluding the following tests:
    • Exudation of plasticizer
    • Acid and corrosive gas emission
    • Melt flow index
    • Carbon black content
    • Environmental stress crack resistance
  • AS/NZS 5000.1 (Working voltages up to and including 0.6/1 (1.2) kV)
    AS/NZS 5000.2 (Working voltages up to and including 450/750 V)
  • AS/NZS 1125 (excluding clause 2.2)
  • AS/NZS 1125 (excluding clause 2.2)

Electrical plugs, sockets, lead assemblies and related components

Electrical safety

Ball pressure; Dimensional assessment including creepage and clearance; Fire hazard assessment; Glow wire flammability; Needle flame; Proof and comparative tracking index; Temperature; Vertical and horizontal flammability; Visual examination

  • AS/NZS 60695.2.10
  • AS/NZS 60695.2.11
  • AS/NZS 60695.2.12
  • AS/NZS 60695.2.13
  • AS/NZS 60695.10.2
  • AS/NZS 60695.11.5
  • AS/NZS 60695.11.10
  • AS/NZS 60695.11.20
  • AS/NZS 60112
  • IEC 60695-2-10
  • IEC 60695-2-11
  • IEC 60695-2-12
  • IEC 60695-2-13
  • IEC 60695-10-2
  • IEC 60695-11-5
  • IEC 60695-11-10
  • IEC 60695-11-20
  • IEC 60112

Luminaires

Electrical safety

Dimensional assessment including creepage and clearance; Electrical characteristics; Endurance and resistance to external conditions; Energy measurement; Fire hazard assessment; Firmware assessment; Function assessment including abnormal operation; Insulation and electrical protection measurement; Mechanical assessment; Temperature; Visual examination

  • AS/NZS 60598.1
  • AS/NZS 60598.2.1
  • AS/NZS 60598.2.2
  • AS/NZS 60598.2.3
  • AS/NZS 60598.2.4
  • IEC 60598-1
  • IEC 60598-2-1
  • IEC 60598-2-2
  • IEC 60598-2-3
  • IEC 60598-2-4

Power tools – Electric

Electrical safety

Dimensional assessment including creepage and clearance; Electrical characteristics; Endurance and resistance to external conditions; Energy measurement; Fire hazard assessment; Firmware assessment; Function assessment including abnormal operation; Insulation and electrical protection measurement; Mechanical assessment; Temperature; Visual examination

  • AS/NZS 62841.1
  • AS/NZS 62841.2.1
  • AS/NZS 62841.2.3
  • AS/NZS 62841.2.5
  • AS/NZS 62841.2.10
  • AS/NZS 62841.2.11
  • AS/NZS 62841.4.2
  • IEC 62841-1
  • IEC 62841-2-1
  • IEC 62841-2-3
  • IEC 62841-2-5
  • IEC 62841-2-10
  • IEC 62841-2-11
  • IEC 62841-4-2

Electrical safety

Dimensional assessment including creepage and clearance; Electrical characteristics; Endurance and resistance to external conditions; Energy measurement; Fire hazard assessment; Firmware assessment; Function assessment including abnormal operation; Insulation and electrical protection measurement; Mechanical assessment; Temperature; Visual examination

  • AS/NZS 60745.1
  • AS/NZS 60745.2.1 (2009)
  • AS/NZS 60745.2.3 (2011)
  • AS/NZS 60745.2.5 (2011)
  • AS/NZS 60745.2.11 (2009)
  • AS/NZS 60745.2.15 (2010)
  • IEC 60745-1 (2006)
  • IEC 60745-2-1
  • IEC 60745-2-3
  • IEC 60745-2-5 (2010)
  • IEC 60745-2-11
  • IEC 60745-2-15

Evaluation of electrical appliances and devices – Energy efficiency classification

Air conditioners and heat pumps; Heat pumps; Liquid chilling devices

Energy labelling and minimum energy performance standards (MEPS) evaluation

Calculations for energy labelling; Evaluation of test results against stated performance criteria; Visual assessment of marking and other attributes against stated criteria

  • AS/NZS 3823.2
  • AS/NZS 4776.2
  • AS/NZS 4965.2

Clothes dryers; Dishwashers; Washing machines

Energy labelling and minimum energy performance standards (MEPS) evaluation

Calculations for energy labelling; Evaluation of test results against stated performance criteria; Visual assessment of marking and other attributes against stated criteria

  • AS/NZS 2007.2
  • AS/NZS 2040.2
  • AS/NZS 2442.2

Freezers; Refrigerators

Energy labelling and minimum energy performance standards (MEPS) evaluation

Calculations for energy labelling; Evaluation of test results against stated performance criteria; Visual assessment of marking and other attributes against stated criteria

  • AS/NZS 4474
  • AS/NZS 4474.2:2009

Swimming pool pumps

Energy labelling and minimum energy performance standards (MEPS) evaluation

Calculations for energy labelling; Evaluation of test results against stated performance criteria

  • AS 5102.1 (excluding clause 5.9)

Water heaters

Energy labelling and minimum energy performance standards (MEPS) evaluation

Calculations for energy labelling

  • AS/NZS 4692.2

Evaluation of electrical appliances and devices – Performance

Air conditioners and heat pumps

Condensate disposal; Dehumidifier capacity; Dehumidifying effectiveness; Enclosure sweat appraisal; Freeze up appraisal; Maximum operating efficiency; Sensible cooling effectiveness; Sensible heating effectiveness; Standby power; Thermal capacity check; Total cooling effectiveness; Volumetric air flow rate

Calorimetric test; Enthalpy

  • AS/NZS 3823.1.1
  • AS/NZS 3823.1.2
  • AS/NZS 3823.1.3
  • AS/NZS 3823.1.4
  • AS/NZS 3823.1.5
  • AS/NZS 3823.4.1
  • AS/NZS 3823.4.2
  • AS/NZS 3823.4.3
  • AS/NZS 4755.3.1
  • AS/NZS 4776.1.1
  • AS/NZS 4776.1.2
  • AS/NZS 4965.1 (Calorimeter and air enthalpy methods only)
  • AS/NZS 5125.1
  • EN 14511-2
  • EN 14511-3
  • EN 14511-4
  • EN 14825
  • ISO 5151
  • ISO 13253
  • ISO 13256-1
  • ISO 15042
  • ISO 16358-1
  • ISO 16358-2
  • ISO 16358-3
  • AHRI 1160 (I-P)
  • AHRI 1161 (SI)
  • AHRI 1230
  • ANSI/AHAM DH-1
  • AS/NZS 62301

Including liquid chilling packages

Clothes dryers; Dishwashers; Freezers; Refrigerators; Washing machines; Water heaters

Air temperature; Cabinet and chamber volumes; Current; Cycle times; Distribution temperature; Drying effectiveness; Electrical energy consumption; Electrical voltage; Enamel thickness and imperfections; Evaporation efficiency; Ice making capability; Lining solubility; Liquid temperature; Load capacity; Power; Pull down time; Rinsing effectiveness; Standby power; Strength and dimensions of components; Temperature control; Temperature limits in dryers; Vibration; Washing or soil removal; Water consumption; Water extraction effectiveness; Water pressure range; Whiteness retention

Not applicable

  • AS/NZS 4474.1:2007
  • ISO 8561:1995
  • ISO 15502:2005
  • IEC 62552-1
  • IEC 62552-2
  • IEC 62552-3
  • AS/NZS IEC 62552-1
  • AS/NZS IEC 62552-3
  • AS/NZS IEC 62552-3
  • AS/NZS 2007.1
  • AS/NZS 2040.1
  • AS/NZS 2442.1
  • AS 1056.1:1991
  • AS 3498
  • AS/NZS 4692.1
  • NZS 4602
  • NZS 4606.1
  • AS/NZS 60335.2.21
  • AS/NZS 62301

AS 3498 Section 7.2, Appendices A, B, C;

AS/NZS 60335.2.21: Clause 22.47 and Annex AA 22.47

Products and appliances connected to the water supply – Physical evaluation

Combination washer/dryers; Dishwashers

Hydrostatic pressure; Rating of products for water efficiency

Not applicable

  • AS/NZS 6400
  • AS/NZS 4692.1
  • AS 1056.1:1991
  • AS/NZS 6400 (Sections 2.1, 2.2, 2.3, 2.4, 2.5, 2.6, 2.7, Tables 3.1 and 3.2 only)
  • AS/NZS 4692.1 (Clause 2.2.2 only)
  • AS 1056.1:1991 (Clause 2.7 only)

Site No. 15858 – ISO/IEC 17025 (2017)

Calibration

The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise.

Service

Product

Determinant

Technique

Procedure

Limitations

Speed and velocity – Speed measuring devices

Vehicle with digital display

Speed

Direct measurement against a reference standard

  • Vipac Method LI8447

Capability

With Calibration and Measurement Capability of –

  • in the range 30 to 110 km/h
  • 0.5 km/h at speeds of 30 to 45 km/h;
  • 0.7 km/h at speeds of 45 to 65 km/h;
  • 0.9 km/h at speeds of 65 to 80 km/h;
  • 1.2 km/h at speeds of 80 to 110 km/h;

Speed and velocity – Verification of fixed speed detector installations

Inductive loop speed measurement systems; Piezoelectric speed measurement systems; Traffic signal phase systems

Field measurement of AC resistance

Direct electrical measurement

Capability

With Calibration and Measurement Capability of –

  • at 1 kHz in the range 0.1 Ω to 200 Ω
  • 0.05 Ω or 8.3% of reading, whichever is greater

Field measurement of insulation resistance

Direct electrical measurement

Capability

With Calibration and Measurement Capability of –

  • 7.6% of reading in the range from 100 kΩ to 500 MΩ

Field measurement of voltage

Direct electrical measurement

Capability

With Calibration and Measurement Capability of –

  • Voltage measuring equipment (picoscope)
  • Stored waveforms in the range 10 mV to 20 V
  • 5 mV or 5 % of reading, whichever is greater

Field measurement of inductance

Direct electrical measurement

Capability

With Calibration and Measurement Capability of –

  • 1 kHz in the range 10 μH to 2 mH
  • 0.5 μH or 1.5% of reading, whichever is greater

Field measurement of DC resistance

Direct electrical measurement

Capability

With Calibration and Measurement Capability of –

  • 0.05 Ω in the range from 0.1 Ω to 200 Ω

Field measurement of capacitance

Direct electrical measurement

Capability

With Calibration and Measurement Capability of –

  • at 1 kHz in the range 0.5 nF to 1 μF
  • 0.1 nF or 0.6% of reading, whichever is greater

Site No. 669 – ISO/IEC 17025 (2017)

Calibration

The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise.

Service

Product

Determinant

Technique

Procedure

Limitations

Chemical metrology – Gas analysers

Gas analysers

Concentration

Direct measurement by certified reference material

  • In-house method WI-UIN-66
  • Carbon monoxide: (electrochemical) 0 – 0.1% (v/v)
  • Oxygen: (electrochemical) 0 – 25% (v/v)
  • Methane (thermal conductivity): 0 – 100% (v/v)
  • Methane (hot wire): 0 – 100% (v/v)
  • Methane (catalytic combustion): 0 – 100% (v/v)
  • CH4 (semiconductor): 0 – 0.05% (v/v)
  • Methane (infra-red): 0 – 100% (v/v)
  • Propane (thermal conductivity): 0 – 0.1% (v/v)
  • Propane (hot wire): 0 – 100% (v/v)
  • Propane (catalytic combustion): 0 – 100% (v/v)
  • Propane (semiconductor): 0 – 0.1% (v/v)
  • Propane (infrared): 0 – 100% (v/v)
  • Hydrogen sulfide (electrochemical): 0 – 0.01% (v/v)
  • Natural gas (thermal conductivity): 0-100% (v/v)

Capability

With Calibration and Measurement Capability of –

  • Carbon monoxide: Electrochemical: 5% relative or 0.0006% (v/v) over the range 0 – 0.1% (v/v), whichever is greater
  • Oxygen: Electrochemical: 2.5% relative or 0.2% (v/v) over the range 0 – 25% (v/v), whichever is greater
  • Methane: Thermal conductivity: 3% (v/v) over the range 0 – 100% (v/v)
  • Methane: Hot wire: 2% LEL over the range 0 – 100% LEL
  • Methane: Catalytic combustion: 2% LEL over the range 0 – 100% LEL
  • Methane: Semiconductor: 5% relative or 0.0005% (v/v) (whichever is larger) in the range 0 – 0.05% (v/v) and 5% relative in the range 0.05% – 0.1% (v/v)
  • Methane: Infrared: 2% (v/v) from 0 – 100% (v/v)
  • Propane: Thermal conductivity: 2.5% relative or 0.0005% (v/v) over the range 0 – 0.1% (v/v)
  • Propane: Hot wire: 2% LEL over the range 0 – 100% LEL
  • Propane: Catalytic combustion: 2% LEL over the range 0 – 100% LEL
  • Propane: Semiconductor: 5% relative or 0.0005% (v/v) (whichever is larger) in the range 0-0.05% (v/v) and 5% relative in the range 0.05% to 0.1% (v/v)
  • Propane: Infrared: 2% (v/v) from 0 – 100% (v/v)
  • Hydrogen sulfide : Electrochemical: 5% relative or 0.0003% (v/v) over the range 0 – 0.01% (v/v), whichever is greater
  • Natural gas: Thermal conductivity: 3% (v/v) gas/methane over the range 0-100% (v/v) gas/methane

Flow metrology – Flow measuring devices and systems

Coriolis meters; Gas meters; Orifice meters

Volume (and nominal flow rate)

Volumetric transfer

Gaseous flow in the flow rate range of 2 mL/h to 3000 m³/h

Capability

With Calibration and Measurement Capability of –

  • Gaseous flow in the flow rate range of 2 mL/h to 1000 m³/h
  • the greater of: 0.18% of flow rate or 2 mL/h, with a minimum test volume of 1 mL;
  • Gaseous flow In the flow rate range of 1000 m³/h to 2000 m³/h
  • 0.21% of flow rate, with a minimum test volume of 10 L;
  • Gaseous flow in the flow rate range of 2000 m³/h to 3000 m³/h
  • 0.26% of flow rate, with a minimum test volume of 10 L

Flow computers

Volume (and nominal flow rate)

Comparison with a reference meter

  • In-house procedures WI-IN-008 and WI-IN-010

Capability

With Calibration and Measurement Capability of –

  • 0.12% of volume, with a minimum test volume of 2 L

Gaseous volume proving systems; Oil and gas measurement systems

Volume (and nominal flow rate)

Volumetric transfer

2 L to 200 kL

Capability

With Calibration and Measurement Capability of –

  • 0.1% of volume, with a minimum test volume of 2 L

Sonic nozzles

Flow rate

Volumetric transfer

Gaseous flow in the flow rate range up to 500 m³/h

Capability

With Calibration and Measurement Capability of –

  • The greater of: 0.18% of flow rate or 2 mL/h, with a minimum test volume of 1 mL

Pressure metrology – Pressure and vacuum measuring equipment

Barometers

Absolute pressure

Comparison with reference instrument

80 kPa to 105 kPa

Capability

With Calibration and Measurement Capability of –

  • 7 Pa from 80 kPa to 105 kPa

Digital pressure gauges; Manometers; Mechanical pressure gauges; Pressure recorders; Pressure transducers; Vacuum gauges

Absolute pressure; Gauge pressure

Comparison with reference instrument

  • AS 1349

Capability

With Calibration and Measurement Capability of –

  • Gauge pressure
    • 0.01% or 1 Pa (whichever is greater) from -95 kPa to -1.7 kPa
    • 0.5 Pa from -1.7 kPa to 1.7 kPa;
    • 0.01% or 1 Pa (whichever is greater) from 1.7 kPa to 14 MPa
  • Absolute pressure
    • 0.01% or 2 Pa (whichever is greater) from 5 kPa to 14 MPa

Temperature metrology – Temperature measuring equipment

Digital temperature measuring systems

Temperature

Measurement against reference standard

Capability

Integral thermometers in Flow Computers

with Calibration and Measurement Capability of –

  • 0.5°C in the range 10°C to 30°C

Over 50 Years of Engineering Excellence

Accredited

Certified

Members of

Recognised by